Miller Electric MARK VIII-2 Welder User Manual


 
OM-218 Page 18
Ref. ST-144 570-A / Ref. SC-085 382
1 115 Volts AC Duplex
Receptacle RC2
This receptacle supplies up to 10
amperes of 115 volts ac power.
The duplex receptacle is protected
from overload by supplementary
protector CB1 (see Section 6-2).
115V AC
10A
115V AC
OVERLOAD
BREAKER
CLOSED
OPEN
1
4-9. 115 Volts AC Duplex Receptacle
4-10. Connecting Input Power
A. Positioning Jumper Links
ssb5.1* 2/92 Ref. ST-144 569-B
Jumper links allow operation on differ-
ent input voltages and are factory set for
the highest input voltage.
Check input voltage available at site.
Open rear panel access door to check
jumper links.
1 Input Voltage Label
Look at jumper links and compare link
position with unit label. Only one label
will be on unit.
2 Input Voltage Jumper Links
Move links to match input voltage. For
example, use 230 volts position when
230 volts input power is available.
Close rear panel access door or go on
to Section 4-10B.
Tools Needed:
S-006 233-A
TE3 TE2 TE3 TE2 TE3 TE2
230 VOLTS 460 VOLTS 575 VOLTS
3/8, 1/2 in
2
1
Y Turn Off polyweld system, and disconnect input power
before inspecting or installing.
1
2