Miller Electric MARK VIII-2 Welder User Manual


 
S-0008-C
OM-218 Page 13
4-4. Weld Cable Size
Total Cable (Copper) Length In Weld Circuit Not Exceeding*
50 ft Or Less
(15m)
100 ft
(30m)
150 ft
(45 m)
200 ft
(60 m)
250 ft
(70 m)
300 ft
(90 m)
350 ft
(105 m)
400 ft
(120 m)
Welding
Amperes
10 Thru 100% Duty Cycle
100 4 4 4 3 2 1 1/0 1/0
150 3 3 2 1 1/0 2/0 3/0 3/0
200 2 2 1 1/0 2/0 3/0 4/0 4/0
250 1 1 1/0 2/0 3/0 4/0 2-2/0 2-2/0
300 1/0 1/0 2/0 3/0 4/0 2-2/0 2-3/0 2-3/0
350 2/0 2/0 3/0 4/0 2-2/0 2-3/0 2-3/0 2-4/0
400 2/0 2/0 3/0 4/0 2-2/0 2-3/0 2-4/0 2-4/0
500 4/0 4/0 4/0 2-2/0 2-3/0 2-4/0 1000 1000
600 4/0 4/0 2-2/0 2-3/0 2-4/0 1000 1000 2-750
700 4/0 2-2/0 2-3/0 2-4/0 1000 1000 2-750 2-750
800 2-2/0 2-2/0 2-3/0 2-4/0 1000 2-750 2-750 2-1000
900 2-3/0 2-3/0 2-4/0 1000 1000 2-750 2-1000 2-1000
1000 2-3/0 2-3/0 2-4/0 1000 2-7500 2-750 2-1000 2-1000
1250 2-4/0 2-4/0 750 2-750 2-750 2-1000 2-1000
1500 500 750 1000 2-750 2-1000 2-1000
1750 750 1000 2-750 2-1000 2-1000
2000 750 1000 2-750 2-1000
*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. Contact your distributor for
the mm
2
equivalent weld cable sizes.