Miller Electric Metro 250D Welding System User Manual


 
20 OM-402
4.6 Remote 14 Receptacle RC1 Information
Ref. ST-158 9
3
Socket* Socket Information
A 24 volt ac with respect to socket G. Protected by circuit
breaker CB5.
B Contact closure to A completes 24 volt ac contactor
control circuit.
AJ
B
K
I
G Circuit common for 24 volt ac circuit.
B
K
I
C
L
NH
D
M
G
F
C 0 to +10 volts dc output to remote control with respect
to socket D.
E
F
A
D Remote control circuit common.
A
E 0 to +10 volts dc input command signal from remote
control with respect to socket D.
K Chassis common.
*The remaining sockets are not used.