Miller Electric 301 G Welding System User Manual


 
OM-4411 Page 20
5-8. Remote Receptacle Information
Engine runs at weld speed (3000 or 3600 rpm) whenever a device connected to
the remote receptacle is running.
NOTE
Socket* Socket Information
AJ
24 VOLTS AC
A 24 volts ac. Protected by circuit breaker CB5.
AJ
B
K
I
B Not used.
C
L
NH
D
M
G
115 VOLTS AC
I 115 volts ac. Protected by fuse F2
D
M
G
E
F
J Not used.
A/V
C Output to remote control: 0 to +10 volts dc output
to remote control in Stick and TIG modes. +10
volts dc output to remote control in Wire mode.
A/V
AMPERAGE
VOLTAGE
D Remote control circuit common.
VOLTAGE
E DC input command signal: 0 to +10 volts dc from
min. to max of remote control with front panel V/A
control at max.
GND
G Circuit common for 24 volt ac circuits.
GND
K Chassis common.
*The remaining sockets are not used.
Notes