Miller Electric OM-1589 Welder User Manual


 
OM-1589 Page 15
3-8. Front Panel Connections for Gun
Ref. 800 688-B
Tools Needed:
5/8, 11/16, 1-1/8 in
Water-Cooled Guns:
1 Gun Control Cable
Insert plug into Gun Control receptacle, and
tighten threaded collar.
2 Gas Hose
Connect to Gas fitting on feeder.
3 Power/Water Cable
4 Strain Relief
Remove strain relief as shown.
Route cable through strain relief and connect
to Weld/Water From Gun outlet on feeder
(left-hand threads). Reinstall strain relief.
5 Wire Conduit
Route through strain relief. Insert through
front panel. Go to Section 3-6.
6 Water Hose
Connect to Water To Gun fitting on feeder
(left-hand threads).
Air-Cooled Gun:
1 Gun Control Cable
Insert plug into Gun Control receptacle, and
tighten threaded collar.
2 Gas Hose
Connect to Gas fitting on feeder.
3 Power Cable
Route cable through front panel and connect
to power block. See Section 3-7.
4 Strain Relief
Remove strain relief as shown.
5 Wire Conduit
Route through strain relief. Insert through
front panel. Go to Section 3-7.
6
5
4
1
3
2
Water-Cooled
Model Shown