Miller Electric OM-1589 Welder User Manual


 
OM-1589 Page 24
SECTION 6 − SETTING DUAL SCHEDULE PARAMETERS
6-1. Selecting Dual Schedule Pair
Dual Schedule is used with two
consecutive weld programs 1 & 2,
3 & 4, 5 & 6, or 7 & 8. Any program
type (MIG, Adaptive Pulse, or
Pulse) can be combined in dual
schedule.
1 Side Panel Display
Use side panel to turn feature on.
See Menu Guide for detailed pro-
gramming steps.
2 Front Panel Display
Press front panel parameter select
button to select program number.
3 Front Panel Display Control
4 Inc/Dec Switch Used As Dual
Schedule Switch
5 Welding Gun Trigger
. Switch type is set in System
Setup (see Section 6-2).
Selecting dual schedule program A
or B is done by using Display Con-
trol, dual schedule switch, or gun
trigger (depending on system set-
up).
When program B is active, turn
Display Control one click clockwise
to select another pair of dual sched-
ule programs.
. Programs can be rearranged in
desired order using the data
card. See Menu Guide for de-
tailed programming steps.
When dual schedule is On, and Process is selected on the
side panel display, then the side panel increase/decrease but-
tons can be used to change program numbers.
Process
Sequence
>Dua lSchd
Ca rd
>Pr g 1&2
On
2
24. 0V
250 IPM
>Pr g 1
Dua l A
>Pr g 2
Dua l B
>Pr g 3
Dua l A
3
Or
Display
Control
Display
Control
1
4
5