Miller Electric OM-1589 Welder User Manual


 
OM-1589 Page 27
SECTION 8 − SYSTEM SETUP
8-1. System Setup Display Parameters
See Menu Guide for detailed programming steps.
NOTE
Display Setting Notes
>System * Select the process the welding power source is able to do.
>Range * Welding power source minimum and maximum voltage values are always needed. Amperage values are required for
pulse welding. Set values to match welding power source ranges.
>Security With lock on, volts or trim and ipm range of change can be restricted.
>Access When on, restricts use of setup screens.
>Mig Type Default is Off. Set to On only for older CV welding power source without voltage feedback at 14-socket receptacle.
>Voltage Default is 14-pin receptacle. Use V. Sense when more than 50 ft (15m) of weld cable is used (including gun cable
length).
>Arc Start** Use Hot Start only with 450 Ampere Inverter Model welding power source and large diameter wires. The arc starts in
CV and switches to CC.
>Dual Schedule See Section 6-2.
>Trigger When on, trigger can be used to switch between programs that have at least 0.2 seconds of preflow time programmed.
>Remote When on, a DSS-10 can be used to change Volts or Trim, IPM, or Prg depending on where the front panel display > is.
>Arc Time Displays accumulated arc time and cycles.
>Self Test See Section 11-8.
>Wire Feed Choose to display inches per minute or meters per minute and motor type, but installed motor must match selection.
>Memory Program Reset: unit defaults to original factory setting for the last active program. Setup information does not change.
If setup card is in card slot, program will be loaded from card.
System Reset: unit defaults to original factory settings for all programs and setup excluding System, Arc Time, and
Model. If setup card is in card slot, program will be loaded from card.
>Shutdown When on, the system immediately shuts down if no arc voltage is sensed. When off, wire feeds even if no arc voltage
is sensed.
>Name When on, optional data card programs can be named.
>Gas Flow♦♦ Setting must be Meter Off if option is not installed.
>Software Know this when talking with service personnel.
* Automatically set if power source data card is used.
Can be used only when optional data card is inserted.
** Selection does not appear on display when MIG Only is System choice.
♦♦ Must remain set to Meter Off if option is not installed to prevent system error.