Miller Electric Spectrum 1000 Welder User Manual


 
OM-217 Page 30
SECTION 7 HF IN PLASMA CUTTING
7-1. High Frequency In Plasma Arc Cutting (PAC)
high_freq2 4/95 S-0753
1 Plasma Arc Torch
2 High-Frequency Voltage
Used inside torch to ionize gap
between electrode and tip to help
start the pilot arc.
3 Electrode
4 Pilot Arc
5Tip
6 Shield Cup
1
3
5
4
6
2
Work
Plasma Arc Cutting (PAC)
7-2. Sources Of High-Frequency Radiation From Incorrect Installation
50 ft
(15 m)
S-0754
Sources Of Direct High-Frequency
Radiation
1 High-Frequency Source (Plasma Arc
Cutting Power Source)
2 Cables
3 Torch
4 Work Clamp
5 Workpiece
6 Work Table
Sources Of Conduction Of High
Frequency
7 Input Power Cable
8 Line Disconnect Device
9 Input Supply Wiring
Sources Of Reradiation Of High
Frequency
10 Ungrounded Metal Objects
11 Lighting
12 Wiring
13 Water Pipes And Fixtures
14 External Phone And Power Lines
9
3
1
Cutting Zone
13
2
4 5
6
8
7
10
11, 12
14