Miller Electric SuitCase 8VS Welder User Manual


 
OM-1599 Page 14
4-7. Connecting Weld Cable
Ref. 132 808-F / Ref. 802 706
Y Turn Off wire feeder and
welding power source. Stop
engine on welding
generator.
1 User-Suppled Weld Cable
Follow wire manufacturer’s recom-
mendations for weld cable polarity.
2 User-Suppled Male Connector
3 User-Suppled Female
Connector
Push female connector over male
connector, and turn 1/4 turn clock-
wise.
2
1
3
From Wire Feeder
Internal Side View
4-8. Installing And Threading Welding Wire
802 706-A / Ref. ST-159 048-A / S-0627-A
Installing Wire And Adjusting
Hub Tension:
1 Retaining Nut
2 Hub Tension Adjustment Nut
Remove retaining ring, and install
spool so hub pin fits spool hole. Re-
install retaining nut.
Adjust tension nut so only a slight
force is needed to turn spool.
Threading Welding Wire:
3 Pressure Assembly
Adjustment Knob
Lay gun cable out straight.
Open pressure assembly, hold wire
tightly, and cut off end. Push wire
through guides into gun.
Close and tighten pressure assem-
bly. Press Jog switch until wire
comes out gun.
Feed wire against wooden surface,
and tighten knob so wire does not
slip.
Cut off wire, and close door.
Tools Needed:
9/16 in
Pull and hold wire; cut off end.
Hold wire tightly to keep it
from unraveling.
6 in
(150 mm)
1
2
3
WOOD
Tighten
Clockwise