Miller Electric SuitCase 8VS Welder User Manual


 
OM-1599 Page 16
5-2. Controls For CE Models
Ref. 803 626-A / Ref. 802 706-A / Ref. 203 745 / Ref. 203 749
1 Power Control Switch
2 Trigger Hold Switch
Depress the upper part of the
switch (turns trigger hold On) to
weld without holding gun trigger
throughout the weld cycle.
To start weld, press and release
gun trigger. To end weld, press and
release gun trigger.
Depress the lower part of the trigger
hold switch to turn trigger hold Off.
3 Purge Switch
Press switch to momentarily ener-
gize gas solenoid and purge air
from gun, and to adjust shielding
gas regulator.
4 Wire Speed Control
Use control to adjust wire speed
within range selected by switch.
5 Jog Switch
Use Jog position to momentarily
feed welding wire at speed set on
Wire Speed control without ener-
gizing welding circuit or shielding
gas valve.
6 HI/LO Range Switch
Use switch to select high or low wire
speed range. High range is 100 to
700 ipm. Low range is 50 to 350
ipm.
7 CC/CV Switch
Use switch to match wire feeder
with welding power source output.
Close and latch door.
1
Front Panel
Internal Control Panel
3
4
5
Internal Side View
6
7
2
HI
CV
CCLO