5.6 Standard Selection Functions
171
FXCPU Structured Programming Manual
(Application Functions)
1
Outline
2
Function List
3
Function
Construction
4
How to Read
Explanation of
Functions
5
Applied
Functions
6
Standard
Function Blocks
A
Correspondence
between Devices
and Addresses
Cautions
1) Use the function having "_E" in its name to connect a bus.
2) When handling 32-bit data in structured programs, you cannot specify 16-bit devices directly, different
from simple projects. Use labels when handling 32-bit data.
You can specify 32-bit counters directly, however, because they are 32-bit devices.
Use global labels when specifying labels.
Program example
In this example, either one among values stored in devices specified in is output to a device specified
in in accordance with the value specified in using the data type of data stored in devices specified in
.
1) Function without EN/ENO(MUL)
2) Function with EN/ENO(MUL_E)
[Structured ladder]
[ST]
[Structured ladder]
[ST]
s1
d n
s1
MUX
g_int1=2
g_int2=1234
_K
_IN
g_int4=5678
g_int3=5678
_IN
g_int4:=MUX(g_int1,g_int2,g_int3);
MUX_E
EN ENO
g_int4
g_bool1
g_int1
g_int2
_K
_IN
g_bool3
g_int3
_IN
g_bool3:=MUX_E(g_bool1,g_int1,g_int2,g_int3,g_int4);