Mitsubishi Electronics FXCPU Welding System User Manual


 
5 Applied Functions
5.1 Type Conversion Functions
96
FXCPU Structured Programming Manual
(Application Functions)
Program example
In this program, double word [unsigned]/bit string [32-bit] data stored in a device specified in is converted
into word [signed] data, and the data obtained by conversion is output to a device specified in .
1) Function without EN/ENO(DWORD_TO_INT)
2) Function with EN/ENO(DWORD_TO_INT_E)
[Structured ladder]
[ST]
[Structured ladder]
[ST]
s
d
g_int1=9029
DWORD_TO_INT
g_dword1=16#00012345
_DWORD
g_int1 := DWORD_TO_INT(g_dword1);
DWORD_TO_INT_E
EN ENO
g_int1
g_bool1
g_dword1
_DWORD
g_bool3
g_bool3 := DWORD_TO_INT_E(g_bool1, g_dword1, g_int1);