MQ SP-3035 CONCRETE SAW — OPERATION AND PARTS MANUAL — REV. #3 (09/29/06) — PAGE 51
MQ SP-3035 CONCRETE SAW
Lubrication
This saw has six grease fittings. Locations are shown in Figure 38 on the front axle assembly, and
one, (not shown) on the Jackshaft assembly.
Front axle pivot bearings (2)
Hydraulic lift cylinder end (1)
Depth cylinder pivot bracket (2)
Jackshaft pivot (1)
These fittings are easily accessed by raising the saw half way up, and then lifting the rear of the
saw until the blade flanges rest on the ground.
WARNING
To prevent the possibility of crush injury, ensure that
the saw is securely placed on suitable supports before
servicing the lubrication points.
DANGER
Grease each fitting every 25 hours of operation using premium grade
waterproof E. P. (extreme pressure) grease.
Fig. 38 — Grease Fittings and Maximum Cut Depth Stops
F5
F4
F3
F2
F1
Maximum Cut
Depth Stop Bolt
Maximum Cut
Depth Stop Bolts