Panasonic EY6535-U1 Cordless Drill User Manual


 
< TROUBLE > < CHECK > < REMEDY >
No speed-control. <CHECK FET.> NO Replace switch & FET
Even if FET block is defective, it can not be replaced individually. Replace
block.
whole switch block.
Shortcircuit (G: gate) and (S: source), and measure between it and (D:
drain) with switch block.
NOTE:
* FET is sensitive against static electricity.
** The resistance value will vary dependent upon the measurement
range of the tester.
OK
<CHECK SWITCH BLOCK.> NO Replace switch & FET
block.
Weakness of <CHECK ANVIL.> NO Replace anvil.
vibration.
Check wear condition. If no less than 1mm from the corner at (A) side or
0.5mm from the corner at (B) side, anvil is OK.
OK
<CHECK HAMMER BLOCK.> NO Replace driving shaft
Check whether hammer block rotates smoothly when moving shaft of
assembly.
hammer.
OK
<CHECK MOTOR.> NO Replace motor.
Measure no load rotation whether it is more than 1,900rpm with full charged
battery pack.
11
EY6535-U1