16
ASSEMBLY
LEVELING THE TABLE EXTENSIONS
See Figure 9.
The infeed and outfeed table extensions are attached to
the planer. Shipped in a folded, upright position, the table
extensions must be in the down position before planing can
begin. For accurate planing, table extensions must be level
with the planer table.
NOTE: For optimum performance, always check to make
sure the table extensions are level before beginning planing
operations.
Place a straight edge or level across both the planer table
and table extensions.
If adjustment is necessary, lift table extensions and loosen
lock nuts. Adjust stop screws (one on each side) until
extension table is level with planer table.
Press down on the table extension to ensure the table
extension is properly seated.
Tighten lock nuts securely when adjustments are
complete.
loCk nut
StoP
SCrewS
tABle
extenSion
PlAner
tABle
StrAiGht
edGe
tABle
extenSion
Fig. 9