Spectra DG711 Laser Level User Manual


 
Getting Started 4
DG711 and DG511 Pipe Laser User Guide 27
Grade Entry,
Step and Go
Press the + GRADE (button 3) or - GRADE (button 4)
and grade will increase or decrease accordingly. The
longer each button is held down the faster grade will
increase or decrease.
Grade Entry,
Digit Select
1 Press the + GRADE (button 3) or - GRADE
(button 4) to initiate a grade change. All grade digits
will appear and the grade polarity (+ or -) sign will
blink.
2 Use the + GRADE or - GRADE buttons to change
the blinking character to the desired polarity or
digit.
3 Use the LEFT or RIGHT line buttons (button 2 or
button 4) to select which digit to change.
4 When all digits have been changed to the desired
amount, press button 1 (backlight button) to store
the new value and resume normal operation.
(Grade Zero)
Quick Change
Mode
1 Press and hold both grade buttons to zero the
grade.
2 Continuous holding of the grade buttons
increments grade in 1% increments, until 10% is
reached.
3 Once 10% is reached, grade increments in 5%
increments until 40% is reached.
4 Once 40% is reached, grade reverts to -15%.
5 Once -15% is reached, grade reverts to -10%.
6 Once -10% is reached, grade increases in 1%
increments until 0% is reached.
Once 0% is reached, the process repeats.
Table 4.2 Optional features (Continued)
Option Operating Instructions