Spectra DG711 Laser Level User Manual


 
Applications and Setups 5
DG711 and DG511 Pipe Laser User Guide 47
Large Pipe 5.4.14
The laser can be set directly on the
flow line using the various
mounting plates or a 1244 T-bar for
increased stability and an
unobstructed flow line.
1 Set Grade Elevation, and Line
into the Laser for large pipe
applications.
2 Set an adjustment pipe target so
that the targets’ bull’s-eye is at the
same distance above the invert as
your laser.
3 Place the pipe target in the last
section of the pipe that has been
checked to be at the correct grade,
elevation and line.
4 Adjust the pipe target until it’s
level vial reads level.
5 Align the laser to the target’s
bull’s-eye using the line buttons on
the laser or the Wireless Remote.
6 Lay Pipe – Set the target in
each new section of the pipe and
adjust the pipe until the laser
intersects the target’s bull’s-eye
while the target is level.
Level
vial