22
UsingSpotLok mode (like PlaneLok) aligns and holds the plumb beam
automaticallytotheSF601centerpoint(bothaxes)untilexitingthismode.
Automatic-Spot-Match: (likeGradeMatch-twoexistingelevationpoints
will be connected to measure the grade value between these two points)
alignstheplumbbeamautomaticallytotheSF601centerpoint(bothaxes)
andmovesbacktoZ-axisautomaticmodewhiledisplayingthemeasured
Z-axisgradevalue.
Note: WhenAutomaticSpotAlignmentandAutomaticSpot-Matchhavebeen
completed,theUL633turnsoffthefanbeamautomatically.
Note:WithaquickpressandreleaseoftheSF601powerbutton,thefanbeamlensattheUL633willbe
activated/deactivatedwhileapreviousactivatedautomodewillbeexited.
SF601 – Manual/Display Mode
WithaquickpressandreleaseoftheSF601powerbutton,thefanbeamlensattheUL633willbeactivated/
deactivatedwhileapreviousactivatedautomaticmodewillbeexited.
Manual/Display (Spot Search) mode:Ifthefanbeamlenswillbeactivatedandnoautomaticmodehas
beenstarted,theSF601isinmanual/displaymodewheretheREDdirectionLEDsguidetheusertothecenter
position of the fan beam.
Note
:IRcommunicationisdisabled.
ThedirectionLEDsworksimilarlikeusingthepipelasertarget,e.g.,ifthe left top LED is on,theSF601has
tobemovedtotheleft/uppositiontobringthecenterholeintothecenterofthebeam.
All4 LEDs are solid red when the beam is centered.