OPERATION
• When the LED is blinking slowly (once
per second), an over-current condition or a
short circuit has occured. The system has
shut OFF and will not automatically restart.
Correct the fault condition and manually restart
the system.
LOW BATTERY AND OVERTEMP/OVER-
LOAD - Red LEDs
• When both LEDs are blinking, an AC
backfeed has been detected. A backfeed
occurs when AC power from an external
source is connected to the output of the
inverter. Inspect wiring for possible input/output
wiring error. This condition will damage the unit
and must be corrected before further
operation.
TSC (Temperature Sensitive Charging)
This provides for the connection of a
sensor to measure battery temperature for
compensated charging. If no sensor is
connected the charge voltage levels are set to
defaults based on battery type.
OPTIONAL REMOTES
If using one of the remotes, refer to the
installation instructions included with the
remote.
Note: When a Freedom Remote Control
Panel or Link is installed, the jumper included
in the parts plastic bag is
not used in the
Auxiliary Switch Port (AUX SWITCH) on the
front panel of the inverter/charger. See page 23
for more details.
Remote
TSC
Overtemp
Low
Battery
Auxiliary Port