Xantrex Technology jazz 300 Welding System User Manual


 
18
PROBLEM: Battery run time is less than expected.
Possible Cause
AC product power consumption is higher
than rated.
Battery is old or defective.
Battery is not being properly charged.
Power dissipation in DC cables.
Suggested Remedy
Use a larger battery to make up for increased
power requirement.
Replace battery.
Many simple chargers are unable to charge
a battery fully. Replace charger with better
model such as a TRUECHARGE
TM
smart
charger.
Use shorter/heavier DC cables.