Connecting DC Wiring For A Single Battery Or Multiple Batteries
The procedure for installing the DC wiring applies to a single battery or
multiple batteries or battery banks. Figure 2-3 shows the connection
order.
Figure 2-3 DC wiring connection order
WARNING
Truecharge+ cannot be set to deliver different charging
profiles at each output. Therefore all the batteries you are
charging must be the same type, that is, all should be flooded,
or all gel, or all AGM.
13.8/13.4
Cold Warm Hot
14.4/13.514.0/13.1
14.2/13.8
Output Vol ts
Absorption / Float
Batt ery Type
Flooded
Gel
Equa l i z e
Charg ing
Rea dy
Bulk/Absorption/Float 13.5V (fi xe d)
14.6/14.2
TM
14.0/13.114.3/13.4
AGM
14.6/13.7
14.8/13.9
Bulk/Absorption
Battery Temperature
1 3 5 10 20
Status Charging Current (A)
Charger Mode
1 -red
14-black
2 -red
3 -red
4
5
6
10
11
12
789
13
DC Negative Bus