Xantrex Technology TC20+ Battery Charger User Manual


 
Specifications
A–4
AC Input Specifications
Protection Features
Truecharge 20+ Truecharge 40+
AC input voltage range 90 – 135 VAC, 50/60 Hz
Maximum AC input current at
90 VAC
6.5 A
rms
12 A
rms
Typical AC input current at
120 VAC
4.6 A
rms
8.5 A
rms
No-load AC power draw
(without remote panel)
less than 3 watts less than 3 watts
Power factor rated load 0.66 0.68
Efficiency—peak 83% 83%
Surge protection Line-to-neutral surge protector rated at 150 V
Protection features
Battery reverse polarity Internal fuses for each output, non-user replaceable
Safe non-operating
battery voltage
24 VDC maximum
Over-voltage limits Will not start charging if any battery voltage is greater than
15.0 VDC
Will not continue charging if any battery voltage is greater than
16.0 VDC
Output current limit Truecharge 20+
20.5 – 22.5 Adc
Truecharge 40+
41.0 – 44.0 Adc