Yamaha EF6300iSDE Welding System User Manual


 
– 9 –
TEST RESET
RESET TEST
w
q
763-083c
e
763-060
AE00848
G.F.C.I. receptacle
w
TO REDUCE THE CHANCE OF ELECTRICAL
SHOCK:
9 Do not attempt to operate electric devices if
the ground fault circuit interrupter reset button
pops out repeatedly during use.
9 Test the ground fault circuit interrupter during
the pre-operation checks according to the
maintenance instructions on page 36.
9 Remember that only receptacle labeled “GFCI”
have ground fault circuit interrupter protec-
tion.
The G.F.C.I. (Ground Fault Circuit Interrupter) 1 shuts
off power to the protected receptacles if a ground fault
(electrical leak) is detected.
If the reset button 2 pops out 3, the electric devices
connected into the receptacle may be faulty. If this
happens, check the electric devices carefully. If the
electric devices appears to be in good condition, press
the reset button firmly until a click is heard. This will
restore power. If the reset button pops out again, dis-
connect all the electric devices immediately. Have the
electric devices inspected and repaired by a qualified
repairperson before attempting to use them again.
Voltage select switch
cC
Do not operate the voltage select switch while the
engine is running.
1 “120/240V”
When the voltage select switch is turned to “120/240V”
1, the generator supplies both 120V and 240V.
2 “120V”
When the voltage select switch is turned to “120V” 2,
the generator supplies 120V only.
799-7CK
12
NO SWITCHING
DURING OPERATION.
WHEN SWITCHING TO 120V.
THE 120/240V OUTLET
CANNOT BE USED.
120/240V 120V