Yamaha EF6300iSDE Welding System User Manual


 
– 21 –
AE00839
Connection
Alternating Current (AC)
w
Be sure any electric devices are turned off before
plugging them in.
cC
9 Be sure all electric devices including the lines
and plug connections are in good condition
before connection to the generator.
9 Be sure the total load is within generator rated
output.
9 Be sure the receptacle load current is within
receptacle rated current.
9 Do not operate the voltage select switch while
the engine is running.
NOTE:
Make sure to ground (earth) the generator.
When the electric device is earthed, always the gener-
ator must be earthed.
1. Select the voltage select switch position according
to the operating voltage of the electric device.
1 120/240V
2 120V
2. Start the engine.
761-7CKa
3. Plug in to AC receptacle.
NOTE:
To supply both 120V and 240V power sources from
the 4-blade plug receptacle needs special knowledge
of the wiring plug. Please contact a trained electrician
for the wiring of the plugs.
799-7CK
12
NO SWITCHING
DURING OPERATION.
WHEN SWITCHING TO 120V.
THE 120/240V OUTLET
CANNOT BE USED.
120/240V 120V
779-017a
Y
W
X
G
GR
120V
120V
240V
7CK-28199-10_a 08.9.15 17:47 Page 21