– 11 –
AE01087
Overload indicator light (red)
The overload indicator light 1 comes on when an
overload of a connected electrical device is detected,
the inverter control unit overheats, or the AC output
voltage rises. Then, the AC protector will trip, stopping
power generation in order to protect the generator and
any connected electric devices. The AC pilot light
(green) will go off and the overload indicator light (red)
will stay on, but the engine will not stop running.
When the overload indicator light comes on and power
generation stops, proceed as follows:
1. Turn off any connected electric devices and stop
the engine.
2. Reduce the total wattage of connected electric
devices within the rated output.
3. Check for blockages in the cooling air inlet and
around the control unit. If any blockages are
found, remove.
4. After checking, restart the engine.
NOTE:
The overload indicator light may come on for a few
seconds at first when using electric devices that
require a large starting current, such as a compressor
or a submergible pump. However, this is not a mal-
function.
1
763-7CKd
707-7XFb
Fuel tank cap
Remove the fuel tank cap by turning it counterclock-
wise.
7CK-28199-10_a 08.9.15 17:47 Page 11