Agilent Technologies 6843A Welding System User Manual


 
3 - Language Dictionary
102
System Commands
The system commands control the system-level functions of the ac source.
Subsystem Syntax
SYSTem
:CONFigure <mode> Selects the operating mode of the ac source (NORM | IEC)
:NOUTputs <n> Select the number of output phases ( 1 or 3 )
:ERRor? Returns the error number and error string
:VERSion? Returns the SCPI version number
:LANGuage <language> Sets the programming language (SCPI | E9012)
:LOCal Go to local mode (RS-232 only)
:REMote Go to remote mode (RS-232 only)
:RWLock Go to remote with lockout mode (RS-232 only)
SYSTem:CONFigure
Agilent 6812B, 6813B, 6843A Only
This command sets the overall operating mode of the ac source. The choices are:
NORMal
Causes the unit to operate in standard ac source mode.
IEC
Modifies the basic behavior of the transient and measurement systems to facilitate
harmonic and flicker emissions testing. (IEC mode is automatically selected when running
the Agilent 14761A Harmonic and Flicker Emissions Tests software application.)
Refer to SYSTem:CONFigure in appendix E for more information about the differences between Normal
mode and IEC mode.
Command Syntax
SYSTem:CONFigure <mode>
Parameters
NORMal | IEC
*RST Value
NORMal
Examples
SYST:CONF NORM
Query Syntax
SYSTem:CONFigure?
Returned Parameters
<CRD>
Related Commands
ABORt MEAS:ARR:CURR MEAS:ARR:VOLT SENS:WIND