Agilent Technologies 6843A Welding System User Manual


 
3 - Language Dictionary
64
CURRent:PEAK:TRIGgered
Agilent 6811B, 6812B, 6813B, Only
This command sets the output limit of the absolute value of peak instantaneous current when a step or
pulse transient is triggered.
Command Syntax
[SOURce:]CURRent:PEAK:TRIGgered <NRf+>
Parameters
refer to Specifications Table in User’s Guide
Unit
A
(peak amperes)
*RST Value
13 (Agilent 6811B/6812B)
26 (Agilent 6813B)
Examples
CURR:PEAK:TRIG 15
Query Syntax
[SOURce:]CURRent:PEAK:TRIG?
Returned Parameters
<NR3>
Related Commands
CURR:PEAK CURR:PEAK:MODE
CURRent:PROTection:STATe
This command enables or disables the overcurrent (OC) protection function. If the overcurrent protection
function is enabled and the exceeds the programmed level, then the output is disabled and the
Questionable Condition status register OC bit is set (see Chapter 4 under “Programming the Status
Registers”). An overcurrent condition can be cleared with OUTPut:PROTection:CLEar after the cause of
the condition is removed.
NOTE: Use OUTP:PROT:DEL to prevent momentary current limit conditions caused by
programmed output changes from tripping the overcurrent protection.
Command Syntax
[SOURce:]CURRent:PROTection:STATe<bool>
Parameters
0 | 1 | OFF | ON
*RST Value
OFF
Examples
CURR:PROT:STAT 0CURR:PROT:STAT OFF
Query Syntax
[SOURce:]CURRent:PROTection:STATe?
Returned Parameters
0 | 1
Related Commands
OUTP:PROT:CLE OUTP:PROT:DEL