Agilent Technologies 6843A Welding System User Manual


 
Language Dictionary - 3
103
SYSTem:CONFigure:NOUTputs
Agilent 6834B Only
This command selects the number of output phases for ac sources that have single-phase and three-
phase switchable capability. This selection is stored in non-volatile memory and is retained after power-off.
The execution of this command disables all outputs, reconfigures the current readback and programming
calibration constants, returns all lists and *RCL states to their factory default states, and reboots the ac
source. Note that this may require you to reprogram the lists and recall states each time the outputs are
switched.
Command Syntax
SYSTem:CONFigure:NOUTputs <NR1>
Parameters
1 or 3
Examples
SYST:CONF:NOUT 1
Query Syntax
SYSTem:CONFigure:NOUTputs?
Returned Parameters
<NR1>
SYSTem:ERRor?
This query returns the next error number followed by its corresponding error message string from the
remote programming error queue. The queue is a FIFO (first-in, first-out) buffer that stores errors as they
occur. As it is read, each error is removed from the queue. When all errors have been read, the query
returns “0, No Error”. If more errors are accumulated than the queue can hold, the last error in the queue
is
“-350, Too Many Errors”.
Query Syntax
SYSTem:ERRor?
Parameters
None
Returned Parameters
<NR1>, <SRD>
Examples
SYST:ERR?
SYSTem:VERSion?
This query returns the SCPI version number to which the ac source complies. The value is of the form
YYYY.V, where YYYY is the year and V is the revision number for that year.
Query Syntax
SYSTem:VERSion?
Parameters
None
Examples
SYST:VERS?
Returned Parameters
<NR2>