Detailed description of RS commands
DLI
Syntax
Result
See also: DLR
DLR
Syntax
Result
See also: DLI, LNG, SEP, SHT
Enables DataLogger operation (RS232 only)
#adrDLR<CR>[<LF>]
#adr,sssss,nnnnn,iiii,ttttt,uuuu.o,www,ppp,vvv
Returns current values :
sssss : current speed (rpm)
nnnnn : speed set point (rpm)
iiii : current value (mA)
ttttt :
pump operating time (hours)
uuuu.o:
(reserved)
www : pwm
(reserved)
ppp : pump temperature (°C)
vvv : variator temperature (°C)
The main characteristics of the pump and its controller are sent over
the RS link, at the rate dened by the DLI command.
Note: any new characters arriving on the serial port (RS 232) will
cancel the automatic DataLogger transmission.
Denes the DataLogger transmission interval
#adrDLIxxx<CR>[<LF>]
xxx: DataLogger transmission interval in seconds
condition: 001 xxx 255
#adr,ok or Err2
Note: if ok, the interval sent is stored in user memory.