Alcatel Carrier Internetworking Solutions ACT 250 Paint Sprayer User Manual


 
Commissioning
Alcatel Vacuum Technology France - ACT 250 addendum
20
January 2001
Detailed description of RS commands
OPT
Syntax
Result
See also: SEL
Used to select possible user choices
#adrOPT2 n<CR>[<LF>]
choice of temperature unit:
n = 0 : degrees Centigrade
n = 1 : degrees Fahrenheit
#adr,ok
Comment: The choice of the temperature unit affects
the results of the DLR and STA strings.
RPM
Syntax
Result
See also: NSP, SBY
Denes the speed set point in stand-by mode
#adrRPM nnnnn<CR>[<LF>] or #adrRPMnnnnn<CR>[<LF>]
#adr,ok or #adr,ErrX
X = 1, out of range; 2, parameters ; 3, context (not in Stand-by mode)
Comment: if ok, the new speed is automatically stored in user
memory.
Saves the internal parameters in user memory
#adrSAV<CR>[<LF>]
#adr,ok
Saves the current context (except for running-in cycles). If this
command is sent when the pump is powered up, it can for example
allow automatic re-start in the event of a power cut.
SAV
Syntax
Result