9.2. MAINTENANCE AT THE END OF THE WORKING DAY
9.2.1.
Disconnect electric and pneumatic connections. (Main Switch must be on “0”
position)
9.2.2.
Remove all burr, chip and foreign materials from the machine surfaces. If it is
necessary to clean the inside of the blade guard, remove the front cover, use gloves to
protect your hands from the sharp edges of the blade.
9.2.3.
If water or water based liquids were used during cutting, dry the machine with a dry
cloth after the operation is finished.
9.2.4.
Apply a thin layer of machine oil to protect the table against corrosion. If the
machine will not be used for a long time, lubricate with a protective oil.
9.2.5.
Don’t use materials for cleaning the machine, which could damage its paint.
9.2.6.
Lubricate both surfaces of the saw blade with machine oil in order to protect it
against corrosion.
10. TROUBLESHOOTING GUIDE
Here are some recommendations for solving urgent problems. If the trouble cannot be
solved, or if you have a problem other than those described hereunder, please contact
our technical service or your nearest dealer.
TROUBLE CAUSES REMEDY
Not cooling the saw blade surfaces
Lubricating the saw blade cutting
surfaces,
Using of cooling liquid
Using of damaged or blunt saw blade
Check the saw blade teeth. Replace
if necessary.
Low surface quality (at aluminum and
similar materials) :
Rough surface,
Large chip,
Not homogenous surface,
Saw blade traces visible
Saw blade moves to quick
The cutting speed is too high for the
material. Decrease the cutting
speed.
Motor does not work (Start button is
pressed, not working)
No power supply to the machine. Check the electric cable
connections.
Check the electric power sockets.
Motor is working but the pneumatic
clamp pistons do not work.
The air supply connections are missing, or the air
pressure is too low.
Check the air compressor
connections.
Adjust the air pressure between 6-8
Bar on the conditioner.
The saw blade rotates in reverse
direction.
The electric connection, the power cable or the
connection at the panel is wrong.
Let the electric connections carry
out by a qualified electrician.