Festool PD561432 Cordless Saw User Manual


 
Supplemental Owner’s Manual 23
Installing the Imperial Depth Gauge
The TS 55 REQ comes with an optional imperial depth gauge
sticker to replace the standard metric depth gauge.
1. Set the depth gauge pointer to its maximum setting.
2. Using a sharp pencil, carefully mark the zero-depth posi-
tion of the depth gauge on the blade housing.
Mark the zero-
depth position.
3. Peel back no more than 1/3 of the paper backing from
the top of the sticker. Peeling the paper back at a slight
angle (as shown) will reduce the likelihood of kinking the
sticker later.
Important: Notice that the top of the sticker has the
zero-depth indicator, and the numbers increase as
they go down.
4. Carefully position the sticker over the existing gauge with
the zero-depth aligned with the pencil mark you made
above, and straight along the edge of the blade cover.
Paper
Backing
Align with
pencil mark.
5. Taking care not to kink the sticker, tuck the bottom under
the depth gauge pointer.
6. Make sure the sticker is properly aligned along the edge
of the blade cover, peel back more of the paper backing,
and press the sticker down.
7. Raise the depth pointer back toward zero, peel back the
rest of the paper backing, and nish adhering the rest of
the sticker.
Peel back
more of the
paper backing.
Tuck the
sticker under
the pointer.