5. If you are lubricating the dosing valves, remove
the plug (73d) and gasket from the valve port (V)
closest to the TSL cup. Check that the o-ring is
in place on the barbed fitting (73b). Apply low
strength thread adhesive and install the fitting in
the valve port (V). NOTE: Do not confuse the
valve port (V) with the air port (W).
NOTE: If you are not lubricating the dosing
valves, remove the unused barbed fittings (73b)
from the bottom of the TSL cup (73). Apply low
strength thread adhesive and install the plugs
and gaskets supplied with the kit.
6. Cut the tubing (73c) to length as required.
Connect the TSL cup fittings to the fittings on the
pump and valves. TSL is gravity-fed from the
cup to the pump and valves; position the fittings
and tubing to prevent kinks and enable the TSL
to flow freely.
7. Fill the cup with TSL.
NOTE: If TSL leaks from the rod guard of the
color (70 cc) pump, be sure the lower u-cup seal
is installed in the lower throat cartridge.
Solvent Meter
Accessory
To install Solvent Meter Kit 280555, see manual
308778.
NOTE: Instal
l the solvent meter downstream of the
solvent cuto
ff switch near the base unit.
Light Tower A
ccessory
To install Light Tower Kit 24K337, see manual
3A1906.