Graco 332709B Paint Sprayer User Manual


 
Troubleshootin
g
Error Code Tro
ubleshooting
System errors alert you of a problem and help
prevent off-ratio spraying. There are three types:
Advisory, Deviation, and Alarm.
An Advisory r
ecords an event in the system, and will
clear itself
after 60 seconds.
A Deviation records an error in the system but does
not shut down the equipment. The deviation must be
acknowledged by the user.
If an Alarm occurs, operation stops.
If any of th
e three types occur:
Alarm buzzer sounds (unless in silent mode).
Alarm popup screen shows the active alarm code.
Status bar on the Advanced Display Module shows
the active alarm code.
Alarm is saved in the date/time stamped log.
NOTE: When an error occurs be sure to determine
the code before resetting it. If you forget which code
occurred, the Errors screen displays the 200 most
recent errors, with date, time, and description.
NOTE: In some
error codes listed below, a # symbol
is shown as th
e last digit. This symbol represents the
applicable
pump number, which can vary. The unit’s
display wil
l show the applicable pump number as the
last digit i
n the code.
Code
Type Description Problem
Cause Solution
B9A0 Advi-
sory
Volume
Rollove
rA
Current
Batch counter for
material A rolled over.
The tota
lizer has
reached
maximum
capable
value and
starte
doveratzero.
n/a
B9AX Advi-
sory
Volume
Rollover A
Lifetime
Grand total counter for
material A rolled over.
The totalizer has
reached maximum
capable value and
started over at zero.
n/a
B9B0 Advi-
sory
Volume
Rollover B
Current
Batch
counter for
mater
ial B rolled over.
The totalizer has
reached maximum
capable value and
started over at zero.
n/a
B9BX Advi
-
sory
Volu
me
Roll
over B
Life
time
Grand total counter for
material B rolled over.
The t
otalizer has
reac
hed maximum
capa
ble value and
star
ted over at zero.
n/a
B9D#
Advi-
sory
Volume
Rollover
Pump #
Grand total counter for
pump # rolled over.
The totalizer has
reached maximum
capable value and
started over at zero.
n/a
332709B
11