Troubleshootin
g
Code
Type Description Problem
Cause Solution
EQU2
Record
USB Sys.
Settings
Uploaded
Settings were
uploaded from
USB
drive.
User installe
dUSB
device in ADM U
SB
port.
n/a
EQU3
Record
USB Cus-
tom Lang.
Down-
loaded
Custom Language was
downloaded to USB
drive.
User installed USB
device in ADM USB
port.
n/a
EQU4
Record
USB
Custom
Lang.
Uploaded
Custom Language was
uploaded from USB
drive.
User installed USB
device in ADM USB
port.
n/a
EQU5
Record
USB Logs
Down-
loaded
Data logs were
downloaded to USB
drive.
User inst
alled USB
device in
ADM USB
port.
n/a
ES00
Advi-
sory
Factory
Defaults
Record of defaults
being loaded.
n/a
EVUX Advi-
sory
USB
Disabled
USB drive has been
inserted, downloading
is disabled.
Configuration of
system is blocking
data transfer.
Change configuration
to enable USB
download function.
There is a restriction
on the outlet side of the
pump or color stack.
Make sure there are
no restrictions in the
color stack and that
thedumpvalveis
actuating.
F1F#
Alarm Flow Low
Fill Pump #
There has been no/low
flow during a fill pump
operation.
Thic
k viscosity
pain
t requires more
pres
sure to pump.
Incr
ease non-mix
pres
sure if necessary
to cr
eate flow during
the fi
ll function.
F1S#
Alarm Flow Low
Purge
Pump #
There has been no flow
or low flow during a
pump purge operation.
Restriction in the outlet
side of the pump or
color stack resulting in
the solvent flow being
too low.
Make sure there are
no restrictions in the
system. Increase
non-mix pressure if
necessary to create
flow during the purge
function.
F6
F#
Alarm Press.
Sens.
Removed
Inlet #
No inlet pressure
transducer is detected
when the system is
expecting one.
Disconnected
transducer.
Ve
rify transducer
is
connected
p
roperly. Replace if
r
econnecting does not
e
liminate the alarm.
16 332709B