Graco 333309E Paint Sprayer User Manual


 
Performance Charts
333309E 33
Performance Charts
2.5” Air Motor with 1:1 and 3:1 Lower Pump Ratio
100 cc/cycle
2.5” Air Motor with 2:1 and 5:1 Lower Pump Ratio
150 cc/cycle
* See Note in Technical Data, page 52.
0 0.2
(0.8)
0.4
(1.5)
0.6
(2.3)
0.8
(3.0)
1.0
(3.8)
815 3038
0
50
(0.3, 3)
100
(0.7, 7)
150
(1.0, 10)
200
(1.4, 14)
250
(1.7, 17)
300
(2.0, 20)
350
(2.4, 24)
1
(0.03)
2
(0.06)
3
(0.08)
4
(0.1)
5
(0.14)
6
(0.17)
7
(0.2)
2320*
B
C
B
C
Cycles per Minute
Fluid Flow gpm (lpm) tested in No. 10 weight oil
Air Flow scfm (m
3
/min)
Fluid Outlet Pressure psi (MPa, bar)
KEY
B
=
65 psi (0.45 MPa, 4.5 bar)
C
=
40 psi (0.28 MPa, 2.8 bar)
=
fluid flow
=
air consumption
0 0.32
(1.20)
0.60
(2.25)
0.91
(3.45)
1.20
(4.50)
1.51
(5.70)
815 3038
0
50
(0.3, 3)
100
(0.7, 7)
150
(1.0, 10)
200
(1.4, 14)
250
(1.7, 17)
1
(0.03)
2
(0.06)
3
(0.08)
4
(0.1)
5
(0.14)
6
(0.17)
7
(0.2)
8
(0.23)
9
(0.25)
2320*
A
B
C
A
B
C
Cycles per Minute
Fluid Flow gpm (lpm) tested in No. 10 weight oil
Air Flow scfm (m
3
/min)
Fluid Outlet Pressure psi (MPa, bar)
KEY
A
=
100 psi (0.7 MPa, 7.0 bar)
B
=
70 psi (0.48 MPa, 4.8 bar)
C
=
40 psi (0.28 MPa, 2.8 bar)
=
fluid flow
=
air consumption