Performance Charts
333309E 35
4.5” Air Motor with 1:1 Lower Pump Ratio (for Polyester Model 24W609)
50 cc/cycle
7.5” Air Motor with 1:1 and 3:1 Lower Pump Ratio
100 cc/cycle
* See Note in Technical Data, page 52.
Cycles per Minute
Fluid Flow gpm (lpm) tested in No. 10 weight oil
Fluid Outlet Pressure psi (MPa, bar)
Air Flow scfm (m
3
/min)
KEY
A
=
100 psi (0.7 MPa, 7.0 bar)
B
=
70 psi (0.48 MPa, 4.8 bar)
C
=
40 psi (0.28 MPa, 2.8 bar)
=
fluid flow
=
air consumption
500
1000
2000
(13.8, 138)
2500
(17.2, 172)
3000
(20.7, 207)
0
0.2
(0.8)
0.4
(1.5)
0.6
(2.3)
0.8
(3.0)
25
(0.71)
20
(0.57)
15
(0.42)
10
(0.28)
5
(0.14)
82338536115 30 45
1500
(10.3, 103)
20*
A
B
C
A
B
C
0 0.2
(0.8)
0.4
(1.5)
0.6
(2.3)
0.8
(3.0)
1.0
(3.8)
815 3038
0
500
(3, 30)
1000
(7, 70)
1500
(10, 100)
2000
(14, 140)
2500
(17, 170)
3000
(21, 210)
3500
(24, 240)
4000
(28, 280)
10
(0.3)
20
(0.6)
30
(0.9)
40
(1.1)
50
(1.4)
60
(1.7)
2320*
Cycles per Minute
0
A
B
C
A
B
C
Fluid Flow gpm (lpm) tested in No. 10 weight oil
Fluid Outlet Pressure psi (MPa, bar)
Air Flow scfm (m
3
/min)
KEY
A
=
95 psi (0.65 MPa, 6.5 bar)
B
=
70 psi (0.48 MPa, 4.8 bar)
C
=
40 psi (0.28 MPa, 2.8 bar)
=
fluid flow
=