Graco 333309E Paint Sprayer User Manual


 
Performance Charts
36 333309E
7.5” Air Motor with 2:1 and 5:1 Lower Pump Ratio
150 cc/cycle
7.5” Air Motor with 4:1 Lower Pump Ratio
125 cc/cycle
* See Note in Technical Data, page 52.
0
500
(3, 30)
1000
(7, 70)
1500
(10, 100)
2000
(14, 140)
2500
(17, 170)
3000
(21, 210)
0 0.4
(1.5)
0.8
(3.0)
1.2
(4.5)
1.6
(6.0)
10 20* 30 40
10
(0.3)
20
(0.6)
30
(0.9)
40
(1.1)
50
(1.4)
60
(1.7)
A
B
C
A
B
C
Cycles per Minute
Fluid Flow gpm (lpm) tested in No. 10 weight oil
Air Flow scfm (m
3
/min)
Fluid Outlet Pressure psi (MPa, bar)
KEY
A
=
100 psi (0.7 MPa, 7.0 bar)
B
=
70 psi (0.48 MPa, 4.8 bar)
C
=
40 psi (0.28 MPa, 2.8 bar)
=
fluid flow
=
air consumption
0 0.5
(1.9)
0.75
(2.8)
0.25
(0.9)
1.0
(3.8)
1.25
(4.7)
15 2210 30 38
0
500
(3, 30)
1000
(7, 70)
1500
(10, 100)
2000
(14, 140)
2500
(17, 170)
3000
(21, 210)
10
(0.3)
20
(0.6)
30
(0.9)
40
(1.1)
50
(1.4)
60
(1.7)
20*
Cycles per Minute
A
B
C
A
B
C
Fluid Flow gpm (lpm) tested in No. 10 weight oil
Fluid Outlet Pressure psi (MPa, bar)
Air Flow scfm (m
3
/min)
KEY
A
=
100 psi (0.7 MPa, 7.0 bar)
B
=
70 psi (0.48 MPa, 4.8 bar)
C
=
40 psi (0.28 MPa, 2.8 bar)
=
fluid flow
=
air consumption