Graco 333309E Paint Sprayer User Manual


 
Performance Charts
34 333309E
2.5” Air Motor with 4:1 Lower Pump Ratio
125 cc/cycle
2.5” Air Motor with 6:1 Lower Pump Ratio
175 cc/cycle
* See Note in Technical Data, page 52.
0 0.25
(1.00)
0.50
(1.87)
0.75
(2.87)
1.00
(3.75)
1.25
(4.75)
815 3038
0
50
(0.3, 3)
100
(0.7, 7)
150
(1.0, 10)
200
(1.4, 14)
250
(1.7, 17)
300
(2.0, 20)
1
(0.03)
2
(0.06)
3
(0.08)
4
(0.1)
5
(0.14)
6
(0.17)
7
(0.2)
8
(0.23)
9
(0.25)
2320*
B
C
B
C
Cycles per Minute
Fluid Flow gpm (lpm) tested in No. 10 weight oil
Air Flow scfm (m
3
/min)
Fluid Outlet Pressure psi (MPa, bar)
KEY
B
=
75 psi (0.52 MPa, 5.2 bar)
C
=
40 psi (0.28 MPa, 2.8 bar)
=
fluid flow
=
air consumption
0 0.37
(1.40)
0.69
(2.62)
1.06
(4.02)
1.39
(5.25)
1.76
(6.65)
815233038
0
50
(0.3, 3)
100
(0.7, 7)
150
(1.0, 10)
200
(1.4, 14)
250
(1.7, 17)
1
(0.03)
2
(0.06)
3
(0.08)
4
(0.1)
5
(0.14)
6
(0.17)
7
(0.2)
8
(0.23)
9
(0.25)
20*
A
B
C
A
B
C
Cycles per Minute
Fluid Flow gpm (lpm) tested in No. 10 weight oil
Air Flow scfm (m
3
/min)
Fluid Outlet Pressure psi (MPa, bar)
KEY
A
=
100 psi (0.7 MPa, 7.0 bar)
B
=
70 psi (0.48 MPa, 4.8 bar)
C
=
40 psi (0.28 MPa, 2.8 bar)
=
fluid flow
=
air consumption