Grizzly G0555X Saw User Manual


 
-8-
G0555X 14" Extreme Series Bandsaw
Serious personal injury could occur if you
connect the machine to the power source
before you have completed the set up pro
-
cess. DO NOT connect the machine to the
power source until instructed to do so.
Amperage Draw
The Model G0555X features a 110V/220V motor
that is prewired for 110V and draws the following
amps under maximum load:
Motor Draw at 110V ............................... 15 Amps
Motor Draw at 220V ............................. 7.5 Amps
Circuit Requirements
We recommend connecting your machine to a
dedicated and grounded circuit that is rated for
the amperage given below. Never replace a circuit
breaker on an existing circuit with one of higher
amperage without consulting a qualified electri
-
cian to ensure compliance with wiring codes
. If
you are unsure about the wiring codes in your
area or you plan to connect your machine to a
shared circuit, consult a qualified electrician.
110V Circuit ...........................................
20 Amps
220V Circuit ...........................................
15 Amps
Figure 1. 6-15 plug and outlet.
NOTICE
The Model G0555X is prewired for 110V
operation. If you plan to use your machine
at 220V, you must rewire the motor. Refer
to the wiring diagram on Page 45. Contact
a qualified electrician if you do not under
-
stand basic wiring procedures.
110V/220V Operation
Plug Type
The Model G0555X comes prewired with a NEMA
5-15 plug. If you wish to rewire the motor to 220V,
we recommend using the following plug (see
Figure
1 for an example):
220V Plug & Receptacle .............................. 6-15
SECTION 2: CIRCUIT REQUIREMENTS
Using a bulb rated for
the incorrect voltage may
cause it to shatter near the
operator, causing person
-
al injury. Only use “safety
coated" and shatter resis
-
tant bulbs rated for the
voltage of your machine.