Grizzly G0790 Planer User Manual


 
-32-
Model G0790 (Mfd. Since 9/15)
7. Loosen motor tensioner bolt (see Figure 35)
to release tension on V-belt.
8. Remove V-belt by rolling it off motor pulley.
9. Place new V-belt over both pulleys. To
tension belt, rotate motor toward front of
machine using moderate force. Hold in place
and tighten motor tensioner bolt.
Cutterhead
Pulley
Approximately
3
8
" Deflection
Motor
Pulley
Figure 34. Correct amount of belt deflection.
Note: V-belt is correctly tensioned when there
is approximately
3
8" deflection when moder-
ate pressure is applied midway between pul-
leys, as illustrated in Figure 34.
10. Re-install belt guard, fan housing, fan, and
fan cover in reverse order that they were
removed.
6. Remove (2) M5-.8 x 10 cap screws that
secure belt guard (see Figure 33).
Figure 33. Fan housing removed and V-belt
exposed.
Belt Guard
Motor Tensioner Bolt