Grizzly G1023 Saw User Manual


 
G1023 Heavy-Duty Table Saw -15-
Figure 18.
Figure 16.
Figure 17.
Table Mount Holes
5. The difference between distance A and dis-
tance B must be equal to or less than
1
64".
6. If the difference is greater than
1
64", loosen
the four (4) table mounting bolts and adjust
the table slightly. Figure 18. Repeat steps 1-
5 until satisfactory. Do not forget to tighten
the table mounting bolts when finished.
Miter Slot to Blade
SECTION 4: ADJUSTMENTS
Your table saw will give the best results if the
miter slot and rip fence are adjusted parallel to
the blade. If they are not exactly parallel, your
cuts and finished work will be lower in quality.
Take the time to adjust your table saw properly. A
few minutes now will be time well spent.
CAUTION: Ensure that the table saw is
unplugged from its power source before making
any adjustments. To check and adjust parallelism
between miter slot and blade:
1. Use a piece of tape to mark the blade in the
gullet between two (2) teeth closest to the
table.
2. Use a steel rule to measure the distance
from the mark on the blade to the edge of the
miter slot. Figure 16.
3. Rotate the blade 180°.
4. Measure the distance from the mark on the
blade to the edge of the miter slot. Figure
17.