Hitachi NT 65MA4 Nail Gun User Manual


 
11
English
(2) Adjust the air pressure to 70 psi (4.9 bar 5
kgf/cm
2
).
Connect the air hose.
Do not load any nails in the Nailer.
Set the switching device to the upward
position (SINGLE ACTUATION
MECHANISM).
(Set the switching device to the upward
position completely as shown in the
diagram. Otherwise, it will not operate
properly.)
Switching Device
Upward position
The nailer must not leak air.
(3) Remove the nger from the trigger and
press the push lever against the wood.
The nailer must not operate.
Depress
Push
Lever
Do not pull Trigger
(4) Separate the push lever from the wood.
Next, point the nailer downward, pull the
trigger and then wait in that position for 5
seconds or longer.
The nailer must not operate.
Pull Trigger
(5) 1 Without touching the trigger, depress
the push lever against the workpiece.
Pull the trigger.
The nailer must operate.
2 Hold the trigger back while separating
the push lever from the wood.
The nailer will remain in operated status
(the driver blade will remain at the
bottom).
3 Remove the nger from the trigger.
Nailer operation will end (the driver
blade will return to the top).
(6) Set the switching device to the downward
position (CONTACT ACTUATION
MECHANISM).
(Set the switching device to the downward
position completely as shown in the
diagram. Otherwise, it will not operate
properly.)
Switching
Device
Downward position
With the Nailer o the workpiece, pull the
trigger.
Depress the push lever against the
workpiece.
The nailer must operate.