Hitachi X200 Welder User Manual


 
Function List
7
Monitoring and main profile parameters
A Group: Standard functions
: Allowed
[
X
: Not allowed
]
Lo Hi
The parameter tables in this chapter have a column titled "Run Mode Edit." An Ex mark x means the parameter cannot be edited; a Check
mark means the parameter can be edited. The table example to the right contains two adjacent marks "x ". These two marks (that can
also be "xx" or " ") correspond to low-access or high-access levels to Run Mode edits (note
Lo and Hi in column heading).
: Allowed
[
X
: Not allowed
]
Function Code Name Range Default Unit
Run mode edit
Monitor
Main Profile
Parameters
F001
F002
F202
F003
F203
F004
d001
d002
d003
d004
d005
d006
d007
d013
d016
d017
d018
d080
d081
d082
d083
d102
d104
Output frequency monitor
Output current monitor
Rotation direction monitor
Process variable, PID feedback monitor
Intelligent input terminal status
Intelligent output terminal status
Scaled output frequency monitor
Output voltage monitor
Cumulative operation RUN time monitor
Cumulative power-on time monitor
Cooling fin temperature monitor
Trip counter
Trip monitor 1
Trip monitor 2
Trip monitor 3
DC bus voltage monitor
Electronic themal monitor
Output frequency setting
Acceleration time (1) setting
Acceleration time (2) setting
Deceleration time (1) setting
Deceleration time (2) setting
Keypad Run key routing
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Hz
A
-
-
-
-
-
V
hr
hr
˚C
events
-
-
-
V
%
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.0/start freq. to 400.0
0.01 to 99.99/100.0 to 999.9/1000. to 3000.
0.01 to 99.99/100.0 to 999.9/1000. to 3000.
0.01 to 99.99/100.0 to 999.9/1000. to 3000.
0.01 to 99.99/100.0 to 999.9/1000. to 3000.
00(Forward)/01(Reverse)
0.0
10.0
10.0
10.0
10.0
00
Hz
sec
sec
sec
sec
-
Expanded functions
A--
b--
C--
H--
P--
A Group: Standard functions
b Group: Fine-tuning functions
C Group: Intelligent terminal functions
H Group: Motor constants functions
P Group: Expansion Card Functions
5 43
ON
OFF
21
AL
ON
OFF
11
e.g. :1,2 : ON
3,4,5: OFF
e.g. :11 : ON
AL : OFF
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
X
Basic setting
A001
A201
A002
A202
A003
A203
A004
A204
Frequency source setting
Frequency source setting, 2nd motor
Run command source setting
Run command source setting, 2nd motor
Base frequency setting
Base frequency setting, 2nd motor
Maximum frequency setting
Maximum frequency setting, 2nd motor
00(Keypad potentiometer)/01(Control terminal)/
02(Function F001 setting)/03(RS485)/10(Calculation result)
01(Control terminal)/02(Run key on keypad)/03(RS485)
30 to maximum freq.
30 to maximum freq.
30 to 400
30 to 400
01
01
01
01
50.
50.
50.
50.
02
0.0
0.0
0.
100.
01
8.
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
100.
00
00
00
1.8
0.0
10.0
0.0
00
00
100.
100.
100.
0.5
0.0
0.
0.0
01
00
00
02
02
60.
60.
60.
60.
02
0.0
0.0
0.
100.
01
8.
0.0
0.0
5.0
10.0
15.0
20.0
30.0
40.0
50.0
60.0
0.0
100.
00
00
00
1.8
0.0
10.0
0.0
00
00
100.
100.
00
0.5
0.0
0.
0.0
01
00
00
02
02
60.
60.
60.
60.
02
0.0
0.0
0.
100.
01
8.
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
100.
00
00
00
1.8
0.0
10.0
0.0
00
00
100.
100.
100.
0.5
0.0
0.
0.0
01
-
-
-
-
Hz
Hz
Hz
Hz
-
Hz
Hz
%
%
-
-
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz
-
-
-
%
%
%
%
-
-
%
%
-
Hz
sec
Hz
sec
-
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Analog input setting
A005
A011
A012
A013
A014
A015
A016
[AT] selection
[O]-[L] input active range start frequency
[O]-[L] input active range end frequency
[O]-[L] input active range start voltage
[O]-[L] input active range end voltage
[O]-[L] input start frequency enable
External frequency filter time constant
02(O/VR)/03(OI/VR)/04(O)/05(OI)
0.0 to maximum freq.
0.0 to maximum freq.
0 to 100
0 to 100
00(use set value)/01(use 0 Hz)
1 to 17
Multi-speed and
jogging
A020
A220
A021
A022
A023
A024
A025
A026
A027
A028
A029-
A035
A038
A039
A041
A241
A042
A242
A043
A243
A044
A244
A045
A245
A051
A052
A053
A054
A055
A056
Multi-speed frequency setting (0)
Multi-speed frequency (2nd), setting 2nd motor
Multi-speed frequency setting (1)
Multi-speed frequency setting (2)
Multi-speed frequency setting (3)
Multi-speed frequency setting (4)
Multi-speed frequency setting (5)
Multi-speed frequency setting (6)
Multi-speed frequency setting (7)
Multi-speed frequency setting (8)
Multi-speed frequency setting (9-15)
Jog frequency setting
Jog stop mode
Torque boost select
Torque boost select 2nd motor
Manual torque boost value
Manual torque boost value, 2nd motor
Manual torque boost frequency adjustment
Manual torque boost frequency adjustment, 2nd motor
V/f characteristic curve selection
V/f characteristic curve selection, 2nd motor
V/f gain setting
V/f gain setting, 2nd motor
DC braking enable
DC braking frequency setting
DC braking wait time
DC braking force during deceleration
DC braking time for deceleration
DC braking / edge or level detection for [DB] input
0.00/start freq. to 9.99
00(free-run stop)/01(deceleration and stop)/02 (DC braking)
00(Manual)/01(Automatic)
00(Manual)/01(Automatic)
0.0 to 20.0
0.0 to 20.0
0.0 to 50.0
0.0 to 50.0
00(VC)/01(Reduced torque)/06 (Reduced torque 1)
00(VC)/01(Reduced torque)/06 (Reduced torque 1)
20 to 100
20 to 100
00(Disable)/01(Enable)/02(Frequency detection)
0.0 to 60.0
0.0 to 5.0
0. to 100.
0.0 to 60.0
00(Edge)/01(Level)
0.0/start freq. to maximum freq.
V/f
Characteristic
DC braking
Run mode
edit
Function Code Name Range
Default
-EF(CE) -U(UL) -R(JP)
Unit
Lo Hi
0.0 to 400.0
0.0 to 999.9
F(Forward)/o(Stop)/r(Reverse)
0.00 to 99.99/100.0 to 999.9/1000. to 9999.
0.00 to 99.99/100.0 to 999.9/1000. to 9999./1000 to 9999(10000 to 99999)
0.0 to 600.0
0. to 9999./1000 to 9999/ 100 to 999 (10000 to 99900)
0. to 9999./1000 to 9999
0.0 to 200.0
0. to 9999.
Displays trip event information
0.0 to 999.9
0.0 to 100.0
X