Hitachi X200 Welder User Manual


 
Function List
8
A Group: Standard functions
b Group: Fine-tuning functions
: Allowed
[
X
: Not allowed
]
: Allowed
[
X
: Not allowed
]
PID Control
PID Control
AVR function
Operation mode and
acc./dec. function
External freq. tuning
Frequency
caluculation
A061
A261
A062
A262
A063
A064
A065
A066
A067
A068
A071
A072
A073
A074
A075
A076
A077
A078
A081
A082
A085
A086
A092
A292
A093
A293
A094
A294
A095
A295
A096
A296
A097
A098
A101
A102
A103
A104
A105
A141
A142
A143
A145
A146
A151
A152
A153
A154
A155
Frequency upper limit setting
Frequency upper limit setting, 2nd motor
Frequency lower limit setting
Frequency lower limit setting, 2nd motor
Jump (center) frequency setting 1
Jump (hysteresis) frequency setting 1
Jump (center) frequency setting 2
Jump (hysteresis) frequency setting 2
Jump (center) frequency setting 3
Jump (hysteresis) frequency setting 3PID Enable
PID Enable
PID proportional gain
PID integral time constant
PID derivative time constant
PV scale conversion
PV source setting
Reverse PID action
PID output limit
AVR function select
AVR voltage select
Operation mode selection
Energy saving mode tuning
Acceleration (2) time setting
Acceleration (2) time setting, 2nd motor
Deceleration (2) time setting
Deceleration (2) time setting, 2nd motor
Select method to switch to Acc2/Dec2 profile
Select method to switch to Acc2/Dec2 profile, 2nd motor
Acc1 to Acc2 frequency transition point
Acc1 to Acc2 frequency transition point, 2nd motor
Dec1 to Dec2 frequency transition point
Dec1 to Dec2 frequency transition point, 2nd motor
Acceleration curve selection
Deceleration curve selection
[OI]-[L] input active range start frequency
[OI]-[L] input active range end frequency
[OI]-[L] input active range start current
[OI]-[L] input active range end current
[OI]-[L] input start frequency enable
A input select for calculate function
B input select for calculate function
Calculation symbol
ADD frequency
ADD direction select
Pot. input active range start frequency
Pot. input active range end frequency
Pot. input active range start current
Pot. input active range end current
Pot.input start frequency enable
0.0/Freq. lower limit setting to maximum freq.
0.0/Freq. lower limit setting (2nd) to maximum freq. (2nd)
0.0/Start freq. to freq. upper limit setting
0.0/Start freq. (2nd) to freq. upper limit setting (2nd)
0.0 to 400.
0.0 to 10.0
0.0 to 400.
0.0 to 10.0
0.0 to 400.
0.0 to 10.0
00(Disable)/01(Enable)
0.2 to 5.0
0.0 to 150.0
0.00 to 100.0
0.01 to 99.99
00([OI] terminal)/01([O] terminal)/02(RS485)/10(Calculation result)
00(OFF)/01(ON)
0.0 to 100.0
00(Enable)/01(Disable)/02(Enabled except during deceleration)
200V class: 200/215/220/230/240
400V class: 380/400/415/440/460/480
00(Normal)/01(Energy-saver)
0.0 to 100.0
0.01 to 99.99/100.0 to 999.9/1000. to 3000.
0.01 to 99.99/100.0 to 999.9/1000. to 3000.
0.01 to 99.99/100.0 to 999.9/1000. to 3000.
0.01 to 99.99/100.0 to 999.9/1000. to 3000.
00(2CH from input terminal)/01(transition freq.)
00(2CH from input terminal)/01(transition freq.)
0.0 to 400.0
0.0 to 400.0
0.0 to 400.0
0.0 to 400.0
00(Linear)/01(S-curve)
00(Linear)/01(S-curve)
0.0 to 400.0
0.0 to 400.0
0. to 100.
0. to 100.
00(Use setting value)/01(0Hz)
00(Digital operator)/01(Keypad potentiometer)
02(O input)/03(OI input)/04(RS485)
00(A141+A142)/01(A141-A142)/02(A141*A142)
0.0 to 400.0
00(Plus)/01(Minus)
0.0 to 400.0
0.0 to 400.0
0.0 to 100.0
0.0 to 100.0
00(Use offect (A151 value))/01(Use 0Hz)
0.0
0.0
0.0
0.0
0.0
0.5
0.0
0.5
0.0
0.5
00
1.0
1.0
0.00
1.00
00
00
0.0
00
200/400
00
50.0
15.00
15.00
15.00
15.00
00
00
0.0
0.0
0.0
0.0
00
00
0.0
0.0
0.
100.
01
01
02
00
0.0
00
0.0
0.0
0.0
100.
01
0.0
0.0
0.0
0.0
0.0
0.5
0.0
0.5
0.0
0.5
00
1.0
1.0
0.00
1.00
00
00
0.0
00
200/400
00
50.0
15.00
15.00
15.00
15.00
00
00
0.0
0.0
0.0
0.0
00
00
0.0
0.0
0.
100.
01
01
02
00
0.0
00
0.0
0.0
0.0
100.
01
0.0
0.0
0.0
0.0
0.0
0.5
0.0
0.5
0.0
0.5
00
1.0
1.0
0.00
1.00
00
00
0.0
02
200/400
00
50.0
15.00
15.00
15.00
15.00
00
00
0.0
0.0
0.0
0.0
00
00
0.0
0.0
0.
100.
01
01
02
00
0.0
00
0.0
0.0
0.0
100.
01
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz
-
-
sec
sec
-
-
-
%
-
V
-
%
sec
sec
sec
sec
-
-
Hz
Hz
Hz
Hz
-
-
Hz
Hz
%
%
-
-
-
-
Hz
-
Hz
Hz
%
%
-
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Run mode
edit
Function Code Name Range
Default
-EF(CE) -U(UL) -R(JP)
Unit
Lo Hi
X
X
X
X
X
X
X
X
X
X
Restart after
instantaneous power
failure
b001
b002
b003
b004
b005
b011
b012
b212
b013
b213
Selection of automatic restart mode
Allowable under-voltage power failure time
Retry wait time before motor restart
Instantaneous power failure / under-voltage trip
alarm enable
Number of restarts on power failure / under-voltage
trip events
Start frequency to be used in case of frequency
pull-in restart
Electronic thermal setting
Electronic thermal setting, 2nd motor
Electronic thermal characteristic
Electronic thermal characteristic, 2nd motor
00(Alarm output)/01(Restart at 0Hz)/
02(Resume after freq. matching)/03(Resume freq. matching then trip)
0.3 to 25.0
0.3 to 100.0
00(Disable)/01(Enable)
00(Restart 16 times)/01(Always restart)
00(frequency at previous shutoff)/01(Max. Hz)/02(Set frequency)
0.2*Rated current to 1.0*Rated current
00(Reduced torque)/01(Constant torque)/02(Reduced torque 2)
00
1.0
1.0
00
00
00
01
01
00
1.0
1.0
00
00
00
01
01
-
sec
sec
-
-
-
A
A
-
-
X
X
X
X
X
X
X
X
X
X
Overload restriction
b021
b221
b022
b222
b023
b223
b028
b228
b029
b030
Overload restriction operation mode
Overload restriction operation mode, 2nd motor
Overload restriction setting
Overload restriction setting, 2nd motor
Deceleration rate at overload restriction
Deceleration rate at overload restriction, 2nd motor
Overload restriction source selection
Overload restriction source selection, 2nd motor
Deceleration rate of frequency pull-in restart
Current level of frequency pull-in restart
00(Disable)/01(Enable)/02(Enable for during acceleration)
0.2*Rated current to 1.5*Rated current
0.1 to 3000.0
00(b022/b222 setting level)/01([O]-[L] analog input)
0.1 to 3000.0
0.2*Rated current to 2.0*Rated current
01
01
1.0
1.0
00
00
0.5
01
01
30.0
30.0
00
00
0.5
-
-
A
A
sec
sec
-
-
sec
A
X
X
X
X
X
X
X
X
X
X
Run mode
edit
Function Code Name Range
Default
-EF(CE)
-U(UL) -R(JP)
Unit
Lo Hi
Lock b031 Software lock mode selection
00([SFT] input blocks all edits)/01([SFT] input blocks edits except
F001 and Multispeed parameters/02(No access to edits)/03(No
access to edits except F001 and Multi-speed parameters)/10(High-
level access,including b031)
01 01
00
1.0
1.0
00
00
00
00
00
01
01
1.0
1.0
00
00
0.5
01
-
X
X
X
Automatic Energy
Saving
X
X
X
Rated current
Rated current
1.5*Rated current
Rated current