Hobart Welding Products 350LX Welding System User Manual


 
OM-356 Page 24
4-7. Meters
1 Voltmeter
Voltmeter displays average voltage
(to the nearest 0.1 V) at the weld
output terminals.
2 Ammeter
Use meter to preset amperage. Me-
ter displays average weld amper-
age output of unit to nearest am-
pere when welding.
1
2
4-8. Amperage Adjustment Control
1 Amperage Adjustment Control
Use control to adjust amperage,
and preset amperage on ammeter
(see Section 4-7). This control may
be adjusted while welding.
For remote amperage control,
front panel control setting is the
maximum amperage available. For
example: If front panel control is set
to 200 A, the range of the remote
amperage control is 3 to 200 A.
For pulse welding, use Amperage
Adjust control to select from 3400
amps of peak amperage (see Sec-
tion 4-12).
For spot welding, use Amperage
Adjust control to select from 3400
amps of peak amperage (see Sec-
tion 4-15).
1
(CE Nameplate Only)
1