Hobart Welding Products HP-70 Welder User Manual


 
. A complete Parts List is available at www.MillerWelds.com
OM-244 013 Page 16
4-12. Wiring Optional 240 Volt Plug (119 172) For Connection To Bobcat, Trailblazer Or
Champion 10,000
Ref. 120 813-D / Ref. 244 405-A
1 Input And Grounding
Conductors
2 Plug Wired for 240 V, 2-Wire
Load
3 Neutral (Brass) Terminal And
Prong (Not Used)
4 Load 1 (Brass)Terminal And
Prong
5 Load 2 (Brass) Terminal And
Prong
6 Ground (Brass) Terminal And
Prong
7 Black And White Input
Conductors
8 Green Or Green/Yellow
Ground Conductor
! Always connect green or
green/yellow wire to ground
terminal, never to a load
terminal. Connect black (L1)
and white (L2) wires to load
terminals.
Tools Needed:
7
Green Or
Green/Yellow
2
3
4
5
6
240V
8
3/16 in.
8
7
6
5
4
3
Plug Front
View
! Engine Control Switch must be set at “RUN”
position ï not “RUN/IDLE”.
! Set generator Fine Adjustment Control to 10
for maximum auxiliary power, if applicable.
1