14
Adjustments
Table Tilt
Referring to Figure 14:
1. Disconnect machine from power source.
2. Loosen the lock knob(s)/lock handle (G).
3. Tilt table up to 45 degrees to the right, or up to
10 degrees to the left.
4. Tighten the lock knob(s)/lock handle.
Note: Table stop bolt (F, Fig. 14) must be removed
to tilt table to the left.
Adjusting 90 Degree Table Stop
Before adjusting the 90º table stop, the blade
tension must be properly adjusted (described in the
Blade Tension section).
To adjust the 90º table stop:
1. Loosen lock knob(s)/lock handle (C, Fig. 15)
and tilt the table until it rests against table stop
bolt (B, Fig. 15); then re-tighten the lock
knob(s)/handle.
2. Use a square (E, Fig. 16) placed on the table
and against the blade to see if the table is 90
degrees to the blade.
3. If an adjustment is necessary, loosen the lock
knob(s)/handle (C, Fig. 15). Tilt the table until it
is square to the blade; then re-tighten the lock
knobs.
4. Loosen lock nut (A, Fig. 15) and turn table stop
bolt (B, Fig. 15) until it contacts the table.
Tighten the nut (A, Fig. 15) to hold table stop in
place. When tightening the nut hold the table
stop bolt in place with a wrench to prevent
movement.
5. If necessary, adjust the pointer (D, Fig. 15) to
zero.
Figure 14
Figure 15
Figure 16