Lincoln Electric 300 DLX Welder User Manual


 
E-2
TROUBLESHOOTING
E-2
RANGER 300 D AND 300 DLX
Observe all Safety Guidelines detailed throughout this manual
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
CAUTION
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENTS(S)
RECOMMENDED
COURSE OF ACTION
Major Physical or Electrical Damage
is Evident.
Engine will not "crank".
Engine will "crank" but not start.
Engine shuts down shortly after
starting.
Engine shuts down while under load.
Battery does not stay charged.
1. Battery is low.
2. Loose battery cable connections.
3. Faulty engine starter motor.
1. Fuel shut off valve is in off posi-
tion.
2. Out of fuel.
3. Engine switch in "OFF" position.
4. High coolant temperature
(Indicator light lit).
5. Faulty fuel solenoid or faulty PC
board.
1. Low oil level. Oil pressure indica-
tor light will flash while engine is
running.
2. Circuit breaker CB9 located in
engine compartment is open. Oil
pressure and charging indicator
lights will not be on when engine
switch is ON and engine is not
running if CB9 is tripped.
1. High coolant temperature
(Indicator light lit).
1. Faulty battery.
2. Loose connections at battery or
alternator.
3. Loose fan belt.
4. Faulty engine alternator.
1. Contact your Local Lincoln Authorized
Field Service Facility.
1. Charge Battery.
2. Inspect, clean and tighten.
3. Contact authorized Kubota Service
Shop.
1. Move lever on fuel filter housing to
"ON" (vertical) position.
2. Fill tank and bleed fuel system. See
MAINTENANCE section
3. Set switch to "ON" position.
4. Check engine cooling system.
5. Contact your Local Lincoln Authorized
Field Service Facility for technical
troubleshooting assistance.
1. Change oil and oil filter and fill to prop-
er level. Start engine and look for
leaks.
2. Reset CB9. If it continues to trip, con-
tact your Local Lincoln Authorized
Field Service Facility for technical
troubleshooting assistance.
1. Reduce load if it is exceeding machine
rating. Add coolant to system if low.
Clean fins on radiator if dirty. Tighten
fan belt if loose.
1. Replace
2. Clean and tighten connections.
3. Tighten. See Maintenance Section.
4. Consult authorized Kubota Service
Shop.