Lincoln Electric 300 DLX Welder User Manual


 
A-1
INSTALLATION
RANGER 300 D AND 300 DLX
A-1
TECHNICAL SPECIFICATIONS - Ranger 300 D (K1522-1), Ranger 300 DLX (K1522-2)
Make/Model Description Speed (RPM) Displacement Starting Capacities
System
Kubota 3 cylinder High Idle 3700 54.9 cu. in
12VDC battery
Fuel: 10 gal.
DH905 26.0 HP @ Low Idle 2150 (898 cc) (Group 45, 495 38 L
Diesel Engine 3600 RPM Full Load 3600 cold crank amps)
Bore x Stroke
1 KW
Starter Oil: 5.4 Qts.
30 A. Alternator 5.1 L
2.83” x 2.90” w/ built in reg.
(72 mm x 73.6mm) Coolant: 5.7 qts.
5.4 L
INPUT - DIESEL ENGINE
RATED OUTPUT - WELDER
HEIGHT WIDTH DEPTH WEIGHT
37.38 in. 24.75 in. 60.50 in. 1093 lbs. (300 D)
1133 lbs. (300 DLX)
949.4 mm 628.7 mm 1528.6 mm 480.8 kg. (300 D)
499.0 kg. (300 DLX)
OUTPUT - GENERATOR
Welding Output Volts at Rated Amps Duty Cycle Max. OCV @ 3700 RPM
DC Constant Current 300 amps
25 volts 100%
AC Constant Current 300 amps
25 volts 100%
80 volts RMS
DC Constant Voltage (300 D) 200 amps
20 volts 100%
DC Constant Voltage (300 DLX) 300 amps
30 volts 60%*
DC Constant Voltage (300 DLX) 280 amps
30 volts 100%
Auxiliary Power
1
12,000 Watts, 60 Hz
120/240 Volts
100 % Duty Cycle
PHYSICAL DIMENSIONS
1. Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to
rated capacity. When welding, available auxiliary power will be reduced.
* Duty cycle is based on a 10 minute period. The machine can be loaded to 300 amps for 6 minutes out of every 10 minute
period.